- Product Type
- 1-port serial device server: serial to Ethernet converter and Modbus RTU to Modbus TCP gateway. One 3-in-1 RS-232 / RS-422 / RS-485 port to one 10/100 Mbps Ethernet port. ARM Cortex-M4, 240 MHz.
- Serial Interface
- 1 port, mode selected in the web interface: RS-232 (TXD, RXD, GND); RS-422 (TX+, TX-, RX+, RX-); RS-485 2-wire (A, B); RS-485 4-wire (TX+, TX-, RX+, RX-). One mode active at a time.
- Serial Standards
- EIA/TIA-232 (ITU-T V.28), EIA/TIA-422 (ITU-T V.11), EIA/TIA-485 (ISO/IEC 8482).
- Baud Rate
- 300 bps to 921,600 bps, custom baud rates supported; RS-232 up to 256 kbps. Non-blocking serial communication.
- Terminal Pinout
- 6-position screwless terminal, 2.54 mm pitch. 1: DC+. 2: DC-. 3: RS-485 A / RS-422 TX+. 4: RS-232 TXD / RS-485 B / RS-422 TX-. 5: RS-232 RXD / RS-422 RX+. 6: RS-232 GND / RS-422 RX-.
변동이 거의 없는 가격
기록 8일
기록된 8일 동안 가격 변동 없음
현재 73,525원
그래프 로딩 중…
가격변동 없음기록된 8일 동안
평균73,525원
기록8일10/14~10/30
아마존 달러 가격을 오늘 환율($1 = ₩1,338)로 환산해 표시합니다. 그날 환율 기준 금액은 그래프를 짚으면 보입니다.
⇄ 다른 상품과 가격 추이 비교한눈에 요약
Mini RS-422/RS-485/RS의 가격은 10월 30일 기준 $54.95(약 73,525원)입니다. 기록된 8일 동안 가격 변동이 거의 없었습니다. 실시간 가격과 재고는 아마존에서 확인할 수 있습니다. 아마존 실시간 가격 확인 ↗
한국까지 예상 비용
- 상품가
- $54.95 (약 73,525원)
- 면세 한도
- $200 (목록통관) · 이하라 면세 예상
- 예상 합계
- 약 73,525원 + 배송비
- 국제 배송비는 아마존 결제 화면에서 확정돼요. 과세 대상이면 배송비에도 세금이 붙어 조금 늘어요.
- 미국에서 보내는 물건은 목록통관 $200, 식품·건강기능식품·의약품(일반통관)은 $150 이하면 면세예요.
- 같은 날 들어오는 여러 건은 합산해서 과세될 수 있어요.
- 세율은 분류별 대표값이고 환율은 오늘 환율 기준이에요. 정확한 세액은 관세청 예상세액 조회에서 확인하세요.
상품 특징
- Computers & Accessories
- Computer Components
- Internal Components
- Serial Port Cards
- Image Unavailable Image not available forColor:
- ONE SERIAL PORT, THREE STANDARDS, SELECTED IN THE WEB INTERFACE - RS-232, RS-422, RS-485 2-wire and RS-485 4-wire are set in software
- there are no jumpers and no DIP switches. The port is one electrical interface configured four ways, not four ports: a single bus is live at a time. Baud 300 bps to 921,600 bps with custom rates, 8 or 9 data bits, none/even/odd parity, 1 or 2 stop bits, non-blocking. RS-232 is three-wire TXD/RXD/GND with no hardware flow control.
- MODBUS RTU TO MODBUS TCP CONVERSION RUNS IN THE UNIT, ENABLED PER ENDPOINT - conversion is a switch on each TCP or UDP endpoint, not a global mode, so one endpoint can convert Modbus while another passes raw bytes on the same device. A Modbus TCP master on port 502 reaches RTU field devices with no driver and no polling script. A polling mode with its own poll timeout and poll delay lets the gateway drive the request cycle instead of the master, which keeps slow slaves from being overrun.
- MQTT CLIENT WITH SEPARATE SUBSCRIBE AND PUBLISH TOPICS - broker address and port 1-65535, client ID, user name and password, keepalive 0 to 65,535 s, and QoS 0, 1 or 2 set independently for subscribe and publish. The serial port is bound to the MQTT client on the Device Connection page, and the payload published is the serial byte stream: register decoding to JSON happens on the platform, not in the gateway. MQTT and the web interface run at the same time.
- FOUR SIMULTANEOUS TCP CLIENTS ON ONE SERIAL PORT, ARM CORTEX-M4 AT 240 MHz - TCP Server, TCP Client, UDP Server, UDP Client and transparent transmission are selectable per endpoint, with a replace-oldest or reject-new link policy and keepalive settable 0 to 65,535 s
- UDP supports unicast and multicast. The Ethernet port is 10/100BASE-T(X) to IEEE 802.3i/802.3u with auto-negotiation and Auto-MDIX, so straight or crossover cable both work.
- 6-POSITION PLUGGABLE 2.54 mm TERMINAL BLOCK, POWER AND SIGNAL IN ONE CONNECTOR - pin 1 (+) and pin 2 (-) take DC 9-50 V. Pin 3 (A) is RS-485+ or RS-422 TX+
- pin 4 (B) is RS-485-, RS-422 TX- or RS-232 TXD
- pin 5 (R) is RS-422 RX+ or RS-232 RXD
- pin 6 (G) is RS-422 RX- or RS-232 signal ground. The plug detaches from the body, so a wired loom stays made up when the unit is swapped off the rail.
- CONFIGURED IN A BROWSER, NO SOFTWARE REQUIRED - IP address, DHCP or static, MAC, serial format, endpoint mode, Modbus conversion and MQTT are all set over HTTP
- a Windows utility and a serial console are available when the network side is not up yet. A virtual serial port driver with automatic reconnection presents the remote port as a local COM port to Windows software that cannot open a socket. Firmware upgrades locally or remotely.
- DC 9-50 V INPUT UNDER 2 W, 6 kV SURGE ON BOTH POWER AND SERIAL, -40 TO +85 C - overload and reverse-polarity protection on the input
- serial surge protection is three-level to GB/T 17626.5 / IEC 61000-4-5, 10/700 us waveform, 6 kV open-circuit peak, 40 ohm source impedance, and the power interface carries the same rating. Level 4 industrial EMC, fanless. Body 24 x 80 x 20 mm, 30 mm deep on the rail
- 35 mm DIN clip fitted, wall-mount plate and AC/DC adapter in the box.